International building code 2018 ibc 2018.
Minimum attic access size ibc.
Clear headroom of not less than 30 inches 762 mm shall be provided in the attic space at or above the access opening.
Where wood shingles or shakes are used a minimum 1 4 inch.
However is a permanent means of access required as in a fixed ladder.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
Access to mechanical appliances installed in under floor areas.
2009 ibc from previous discussions i understand that stairs are not required to attics.
306 3 appliances in attics.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
If the access is located in the ceiling the minimum unobstructed headrom above the opening must be 30 inches measured vertically at some point over the access.
According to the 2006 international residential code r807 1 attic access homes with combustible materials in the ceiling and roof construction must have an access to attic areas that exceeds 30 square feet and with a vertical height of 30 inches or greater.
Attic access r807 1 attic access.
These specs are per r807 1 of the international residential code irc and the residential edition of the florida building code fbc.
Minimum opening size the 2012 international residential code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.
762 mm shall be provided in the attic space at or above the access opening.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
International building code 2015 ibc 2015.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
In buildings with combustible ceiling or roof construction an attic access opening shall be provided to attic areas that exceed 30 square feet 2 8m2 and have a verti cal height of 30 inches 762 mm or greater.
The rough framed opening must be a minimum of 22 inches by 30 inches.
Thanks from the 2009 imc.
From the finished floor to the ceiling shall not be included in any computation of the minimum area thereof.